* Listen_For_Messages.c
*
* Created on: 14 juli 2021
* Author: Daniel Mårtensson
*/
#include "Open_SAE_J1939.h"
/* Layers */
#include "../ISO_11783/ISO_11783-7_Application_Layer/Application_Layer.h"
#include "../Hardware/Hardware.h"
/* This function should be called all the time, or be placed inside an interrupt listener */
bool Open_SAE_J1939_Listen_For_Messages(J1939* j1939) {
uint32_t ID = 0;
uint8_t data[8] = {0};
bool is_new_message = CAN_Read_Message(&ID, data);
if(is_new_message){
/* Save latest */
j1939->ID = ID;
memcpy(j1939->data, data, 8);
j1939->ID_and_data_is_updated = true;
uint8_t id0 = ID >> 24;
uint8_t id1 = ID >> 16;
uint8_t DA = ID >> 8; /* Destination address which is this ECU. if DA = 0xFF = broadcast to all ECU. Sometimes DA can be an ID number too */
uint8_t SA = ID; /* Source address of the ECU that we got the message from */
/* Read request from other ECU */
if (id0 == 0x18 && id1 == 0xEA && (DA == j1939->information_this_ECU.this_ECU_address || DA == 0xFF)){
SAE_J1939_Read_Request(j1939, SA, data);
}else if (id0 == 0x18 && id1 == 0xD9 && DA == j1939->information_this_ECU.this_ECU_address){
SAE_J1939_Read_Request_DM14(j1939, SA, data);
/* Read status from other ECU */
}else if(id0 == 0x18 && id1 == 0xE8 && DA == j1939->information_this_ECU.this_ECU_address){
SAE_J1939_Read_Acknowledgement(j1939, SA, data);
}else if (id0 == 0x18 && id1 == 0xD8 && DA == j1939->information_this_ECU.this_ECU_address){
SAE_J1939_Read_Response_DM15(j1939, SA, data);
}else if(id0 == 0x18 && id1 == 0xD7 && DA == j1939->information_this_ECU.this_ECU_address){
SAE_J1939_Read_Binary_Data_Transfer_DM16(j1939, SA, data);
/* Read Transport Protocol information from other ECU */
}else if(id0 == 0x1C && id1 == 0xEC && DA == j1939->information_this_ECU.this_ECU_address){
SAE_J1939_Read_Transport_Protocol_Connection_Management(j1939, SA, data);
}else if (id0 == 0x1C && id1 == 0xEB && DA == j1939->information_this_ECU.this_ECU_address){
SAE_J1939_Read_Transport_Protocol_Data_Transfer(j1939, SA, data);
/* Read response request from other ECU - This are response request. They are responses from other ECU about request from this ECU */
}else if (id0 == 0x18 && id1 == 0xEE && DA == 0xFF && SA != 0xFE){
SAE_J1939_Read_Response_Request_Address_Claimed(j1939, SA, data); /* This is a broadcast response request */
}else if (id0 == 0x18 && id1 == 0xEE && DA == 0xFF && SA == 0xFE){
SAE_J1939_Read_Address_Not_Claimed(j1939, SA, data); /* This is error */
}else if (id0 == 0x18 && id1 == 0xFE && DA == 0xCA){
SAE_J1939_Read_Response_Request_DM1(j1939, SA, data, 1); /* Assume that errors_dm1_active = 1 */
}else if (id0 == 0x18 && id1 == 0xFE && DA == 0xCB){
SAE_J1939_Read_Response_Request_DM2(j1939, SA, data, 1); /* Assume that errors_dm2_active = 1 */
}else if (id0 == 0x18 && id1 == 0xFE && DA == 0xDA){
SAE_J1939_Read_Response_Request_Software_Identification(j1939, SA, data);
}else if (id0 == 0x18 && id1 == 0xFD && DA == 0xC5){
SAE_J1939_Read_Response_Request_ECU_Identification(j1939, SA, data);
}else if (id0 == 0x18 && id1 == 0xFE && DA == 0xEB){
SAE_J1939_Read_Response_Request_Component_Identification(j1939, SA, data);
}else if (id0 == 0x0C && id1 == 0xFE && DA >= 0x10 && DA <= 0x1F){
ISO_11783_Read_Response_Request_Auxiliary_Estimated_Flow(j1939, SA, DA & 0xF, data); /* DA & 0xF = Valve number. Total 16 valves from 0 to 15 */
}else if (id0 == 0x0C && id1 == 0xC6 && DA == j1939->information_this_ECU.this_ECU_address){
ISO_11783_Read_Response_Request_General_Purpose_Valve_Estimated_Flow(j1939, SA, data);
}else if (id0 == 0x0C && id1 == 0xFF && DA >= 0x20 && DA <= 0x2F){
ISO_11783_Read_Response_Request_Auxiliary_Valve_Measured_Position(j1939, SA, DA & 0xF, data); /* DA & 0xF = Valve number. Total 16 valves from 0 to 15 */
/* Read command from other ECU */
}else if (id0 == 0x0C && id1 == 0xFE && DA >= 0x30 && DA <= 0x3F){
ISO_11783_Read_Auxiliary_Valve_Command(j1939, SA, DA & 0xF, data); /* DA & 0xF = Valve number. Total 16 valves from 0 to 15 */
}else if (id0 == 0x0C && id1 == 0xC4 && DA == j1939->information_this_ECU.this_ECU_address){
ISO_11783_Read_General_Purpose_Valve_Command(j1939, SA, data); /* General Purpose Valve Command have only one valve */
}else if (id0 == 0x0 && id1 == 0x2 && (DA == j1939->information_this_ECU.this_ECU_address || DA == 0xFF)){
SAE_J1939_Read_Address_Delete(j1939, data); /* Not a SAE J1939 standard */
}else{
is_new_message = false; /* The message was not meant for this ECU */
}
/* Add more else if statement here */
}
return is_new_message;
}