Notifications
You must be signed in to change notification settings - Fork 0
/
froeling_mgr.py
149 lines (117 loc) · 7.27 KB
/
froeling_mgr.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
import appdaemon.plugins.hass.hassapi as hass
from froeling import LambdatronicS3100
class FroelingMgr(hass.Hass):
def initialize(self):
self.publish_message(var_name = "froeling_status",
friendly_name = "Status Froeling",
msg_text = "Starting")
self.run_in(self.initialize_froeling, 20)
def initialize_froeling(self, kwargs):
self.publish_message(var_name = "froeling_status",
friendly_name = "Status Froeling",
msg_text = "Initializing")
# initialize everything
self.froeling = LambdatronicS3100(host = '192.168.1.147', port = 23, timeout = 0.1, debug = False)
self.froeling.send_login(mode = "service")
while True:
self.froeling.receive_and_parse()
if self.froeling.init_complete:
break
self.froeling.request_status()
self.publish_message(var_name = "froeling_status",
friendly_name = "Status Froeling",
msg_text = "Active")
# schedule callbacks
self.run_every(self.handle_protocol, "now", 1)
self.run_every(self.publish_measurements, "now+10", 1)
def handle_protocol(self, kwargs):
try:
while self.froeling.receive_and_parse():
pass
except ConnectionError:
print("Froeling connection error, scheduling restart.")
self.schedule_restart()
def schedule_restart(self):
self.publish_message(var_name = "froeling_status",
friendly_name = "Status Froeling",
msg_text = "In restart")
self.restart_app("froeling_mgr")
def publish_measurements(self, kwargs):
self.publish_message(var_name = "froeling_lastdata",
friendly_name = "Letzte Aktualisierung der Heizungsdaten",
msg_text = self.froeling.parameter_values["last_updated"])
self.publish_measurement(var_name = "froeling_boiler_temp",
friendly_name = "Froeling Kesseltemperatur",
value = self.froeling.parameter_values.get("Kesseltemp", 0.0),
unit = "°C")
self.publish_measurement(var_name = "froeling_exhaust_temp",
friendly_name = "Froeling Abgastemperatur",
value = self.froeling.parameter_values.get("Abgastemp.", 0.0),
unit = "°C")
self.publish_measurement(var_name = "froeling_exhaust_temp_target",
friendly_name = "Froeling Abgastemperatur Sollwert",
value = self.froeling.parameter_values.get("Abgas. SW", 0.0),
unit = "°C")
self.publish_measurement(var_name = "froeling_forced_air",
friendly_name = "Froeling Saugzug",
value = self.froeling.parameter_values.get("Saugzug", 0.0),
unit = "%")
self.publish_measurement(var_name = "froeling_prim_air",
friendly_name = "Froeling Prim. Luft",
value = self.froeling.parameter_values.get("Prim.Luft", 0.0),
unit = "%")
self.publish_measurement(var_name = "froeling_sec_air",
friendly_name = "Froeling Sek. Luft",
value = self.froeling.parameter_values.get("Sek.Luft", 0.0),
unit = "%")
self.publish_measurement(var_name = "froeling_ox_rem",
friendly_name = "Froeling Rest-O2",
value = self.froeling.parameter_values.get("Rest-O2", 0.0),
unit = "%")
self.publish_measurement(var_name = "froeling_buffer_temp_top_deg",
friendly_name = "Puffertemperatur oben",
value = self.froeling.parameter_values.get("Puffert.ob", 0.0),
unit = "°C")
self.publish_measurement(var_name = "froeling_buffer_temp_mid_deg",
friendly_name = "Puffertemperatur mitte",
value = self.froeling.parameter_values.get("Puffert.mi", 0.0),
unit = "°C")
self.publish_measurement(var_name = "froeling_buffer_temp_bot_deg",
friendly_name = "Puffertemperatur unten",
value = self.froeling.parameter_values.get("Puffert.un", 0.0),
unit = "°C")
self.publish_measurement(var_name = "froeling_outside_temp_deg",
friendly_name = "Aussentemperatur",
value = self.froeling.parameter_values.get("Außentemp", 0.0),
unit = "°C")
self.publish_measurement(var_name = "froeling_loop_1_target_temp_deg",
friendly_name = "Vorlauftemperatur 1 Sollwert",
value = self.froeling.parameter_values.get("Vorlauft.1sw", 0.0),
unit = "°C")
self.publish_measurement(var_name = "froeling_loop_1_temp_deg",
friendly_name = "Vorlauftemperatur 1",
value = self.froeling.parameter_values.get("Vorlauft.1", 0.0),
unit = "°C")
self.publish_measurement(var_name = "froeling_loop_2_target_temp_deg",
friendly_name = "Vorlauftemperatur 2 Sollwert",
value = self.froeling.parameter_values.get("Vorlauft.2sw", 0.0),
unit = "°C")
self.publish_measurement(var_name = "froeling_loop_2_temp_deg",
friendly_name = "Vorlauftemperatur 2",
value = self.froeling.parameter_values.get("Vorlauft.2", 0.0),
unit = "°C")
self.publish_measurement(var_name = "froeling_board_temp_deg",
friendly_name = "Boardtemperatur",
value = self.froeling.parameter_values.get("Boardtemp.", 0.0),
unit = "°C")
def publish_message(self, var_name, friendly_name, msg_text):
self.set_state(f"sensor.{var_name}",
state = msg_text,
attributes = {"friendly_name": friendly_name})
def publish_measurement(self, var_name, friendly_name, value, unit, meas_type = "power"):
self.set_state(f"sensor.{var_name}",
state = value,
attributes = {"friendly_name": friendly_name,
"unit_of_measurement": unit,
"state_class": "measurement",
"device_class": meas_type})