Code for the Bioreactor device. Created by undergraduate research student Nicolas Montoya under the supervision of Ph.D. student Bryan James at the University of Florida.

Notifications You must be signed in to change notification settings

NicoPowers/BioReactorCode

Repository files navigation

UF's open-source bioreactor device

This repository holds all the software that is used for Dr. Allen's labs' bioreactor device at the University of Florida (Material Science and Engineering department).

The MEGA_Controller.ino code is meant to send commands to the stretch controller (NANO) and flow rate controller (UNO).

The UNO_flow_staticPressure_controller.ino code is meant to run on the UNO and is used to control the position of the vial and vary the pump sinusoidally.

The NANO_stretch_controller.ino code is meant to run on the Nano and is used to control the stretching of the chamber sinusoidally.

Below is the cheat sheet for the commands that can be given to both the UNO and the Nano from the Serial Monitor Terminal of the Arduino Mega (9600 baud rate):

To send commands that affect stretching, all commands must start with a lowercase n (to signify nano). Below are the following commands that you use:

Command Legend

%f => float

%i => integer

%b => boolean (still expressed as an integer; 1 -> true | 0 -> false)

  • no%f to move outwards a distance %f

  • ni%f to move inwards a distance %f

  • nd%f to set the initial displacement, %f, between the plates

  • nx to cancel the oscillation and return stretcher to limit switch plus some initial distance

  • nr%b%i to start oscillation where %b is whether or not to use sinusoidal flow and %i is the repeating distance index (choose from the below array):

    [1.0, 1.25, 1.50, 1.75, 2.00, 7, 7.50, 7.75, 8.0] mm

    Examples:

    • nr01 -> stretch without sinusoidal flow rate distance of 1.25 mm

    • nr11 -> stretch with sinusoidal flow rate distance of 1.25 mm

    • nr03 -> stretch with sinusoidal flow rate distance of 1.75 mm

      The following repeating distances currently work at 1 Hz: 5% Strain: 1.00 mm 1.25 mm 1.50 mm 1.75 mm 2.00 mm

      The following repeating distances currently do not work at 1 Hz (they are less than 1 Hz since our current stepper motor cannot move any faster): 10% Strain: 7 mm 7.25 mm 7.5 mm 7.75 mm 8.0 mm

To send commands to change the vertical height of the water vial and to set constant or sinusoidal flow rate, all commands must start with a lowercase u (to signify UNO). Below are the following commands that you can use:

  • ud%f to move the vial down a certain distance %f (mm)

  • uu%f to move the vial up a certain distance %f (mm)

  • uh to move back to the home position

  • ux to set the current position as the home position

  • uc to check the current distance from the home position

  • uq to toggle the MasterFlex pump on/off

  • ur to enable sinusoidal flow rate (does not start sinusoidal flow rate, only enables it, Nano triggers it so they are sync'd)

    NOTE: If you set a constant flow rate, you MUST re-enable sinusoidal flow rate before you want to do sinusoidal flow control

  • up%f to set the phase, %f (degrees), of the sinusoidal flow rate

  • us%f to set the vertical shift, %f (mL/min), of the sinusoidal flow rate

  • ua%f to set the amplitude, %f (mL/min), of the sinusoidal flow rate

  • ue%f to set the manual (constant) flow rate (this disables sinusoidal flow rate), where %f is the value

  • ut%i to set the tubing size, %i, (16 or 17: Default selected tubing size is 16)

External libraries used can also be found in this repositiory. Schematics and full wiring diagrams are expected to come with version 2.

Designed, built, and programmed by undergraduate research student Nicolas Montoya.

About

Code for the Bioreactor device. Created by undergraduate research student Nicolas Montoya under the supervision of Ph.D. student Bryan James at the University of Florida.