Errata


page 15 -- top of page

found by Keith Roberts of Teledyne LeCroy

The current vector should be on the left and the voltage vector should be on the right. i.e. i=Yv.

page 43 -- middle of the page

found by Keith Roberts of Teledyne LeCroy

The equation for VS as a function of vp and ip has the incorrect sign. The minus sign should be a plus sign.

page 61 -- table 3.7 -- very minor

The second row's description has an erroneous period at the end.

page 80 -- Line 31 of the listing

found by Gus Blando from Samtec

The Touchstone 1.1 standard states that the option line is printed in the following order:

# <frequency unit> <parameter> <format> R <Z0>

but this code is transposing the order of the parameter token and the format token. This generally does not cause a problem, but has been fixed in later software releases.

On a similar note, the specification says that no more than four pairs of numbers should be written on a line. This software always writes the numbers for a single frequency on an entire line. This violates the specification for devices with more than two ports, but also doesn't generally cause a problem. This has also been fixed in later software releases.

page 93 -- equation (4.5)

found by Gus Blando from Samtec

Two elements of the large matrix are incorrect.

SC_{31} should be 0

SC_{41} should have a positive sign, not a negative sign

Fortunately, figure 4.6 is correct.

page 97 -- equation (4.7)

found by Pete Pupalaikis

The same error in equation (4.5) is in equation (4.7)

page 98 -- figure 4.8 and page 99 -- figure 4.9

found by Gus Blando

The stimulus m6 should be labeled m2, and all things referring this should use m2. I wavered while writing this and ended up getting it wrong.

page 100-101 -- equations 4.9--4.12

found by Gus Blando

They have an erroneous SL21 where SL12 belongs

page 359 -- just above equation (12.2)

found by Pete Pupalaikis

I misspelled following. I left out an o and spelled it follwing.

page 497 -- the large equation at the bottom of the page

found by Pete Pupalaikis

the first log should not be italic. It should be upright roman.