trowaSoft v0.5.5.2 - voltSeq: early first step isn't played (or partially played) on RST #11

Closed
DomiKamu opened this issue Feb 19, 2018 · 5 comments
Labels

Comments

@DomiKamu
Copy link

DomiKamu commented Feb 19, 2018

trowaSoft v0.5.5.2.
Windows 7 Pro SP1 x64 (also 10), VCV Rack v0.5.1

Hi Jason,

I report an issue (I've already discovered in previous v0.5.5.1) about voltSeq, lastest v0.5.5.2, VCV

In particular when voltSeq is stopped, then "RST", then "RUN", the early first step is not played (or played too quick, regardling next notes). On next loops however, the first steps (notes) are correctly played however (I mean: at same speed).

EDIT: the culprit seems to be the RESET (button or via RST input) when seq is running, I presume a "timer" doesn't restart at beginning.

Note: VCV Rack audio engine is set at 44100 Hz (like my Saffire Pro 14 ASIO interface).

Regards.

Dominique

@DomiKamu DomiKamu changed the title trowaSoft v0.5.5.2 - voltSeq: early first step isn't played (or partialliy) trowaSoft v0.5.5.2 - voltSeq: early first step isn't played (or partially played) on RST Feb 19, 2018
@chichian
Copy link
Collaborator

Oops. We'll look into it. I thought I had worked on that before but maybe that was only for trigSeq.

@DomiKamu
Copy link
Author

Don't worry! your trowaSoft modules are simply fabulous (I'm experiment OSC together with Lemur on iOS), you'll can fix it for future release (perhaps against VCV Rack v0.6.0), so be sure it's not urgent. I'm considering we're into a fantastic community, and we can help us together as soon as it's possible, it's my state of mind (I've lot of free time b'coz I'm unemployed).

Greetings from Chartres, France.
Dominique.

@j4s0n-c j4s0n-c added the bug label Feb 25, 2018
@j4s0n-c
Copy link
Owner

j4s0n-c commented Mar 30, 2018

This happens because the reset occurs immediately instead of waiting for the next step to keep the timing "on the grid". We will correct this ASAP.

chichian added a commit that referenced this issue Mar 31, 2018
Do not do reset immediately but wait until the next step. #11
@j4s0n-c
Copy link
Owner

j4s0n-c commented Apr 6, 2018

@DomiKamu Have you tried the update to see if this issue can be closed?

@DomiKamu
Copy link
Author

DomiKamu commented Apr 6, 2018

Hi Jason, I've tested yet (voltSeq v0.6.1), of course fixed, I close this issue. Thanks a lot!